General Features3 W (136-174 MHz) Models 3 W (400-470 MHz) Models 512 CH-GID / 128 Zones 12-Key Keypad Models 14 Character Alphanumeric Aliases Backlit Dot Matrix LCD Function/Status LCD Icons Date & 12/24 Hour Time Clock Transmit/Busy/Call Alert/Warn LED On/Off Volume Knob 16-Position...
General Features3 W (136-174 MHz) Models
3 W (400-470 MHz) Models
512 CH-GID / 128 Zones
12-Key Keypad Models
14 Character Alphanumeric Aliases
Backlit Dot Matrix LCD
Function/Status LCD Icons
Date & 12/24 Hour Time Clock
Transmit/Busy/Call Alert/Warn LED
On/Off Volume Knob
16-Position Mechanical Selector
6 Front PF & Menu Keys
2 Side PF Keys
Emergency/AUX Key
500 mW Speaker Audio
Emergency Call Features
Multi-Language Display
KMC-47GPS Speaker Mic Option
KPG-111D Windows® FPU
Flash Firmware Upgrading
MIL-STD-810 C/D/E/F/G
IP67 Water & Dust Intrusion
PC Serial Interface
SDM Manual Input*1
Transparent Data Mode*1
Intrinsically Safe Option
VGS-1 Voice Guide / Voice & GPS Data Storage Option
Digital-General
NXDN® Digital Air Interface
AMBE+2™ VOCODER
6.25 & 12.5 kHz Channels
Over-the-Air Alias
Over-the-Air Programming*2
Paging Call
Emergency Call
All Group Call
Status Messaging*1
Remote Stun/Kill*1
Remote Check*1
Short & Long Data Messages*1
GPS Location with Voice*1
NXDN® Scrambler Included
AES / DES Encryption Options
Digital-Conventional Mode
64 Radio Access Numbers (RAN)
Individual & Group Selective Call
Mixed FM/Digital Operation
Conventional IP Networks
Site Roaming
Digital-Trunkking Mode
Individual Private Call
Group Call & Broadcast Call
Telephone Interconnect*3
Transmission Trunked Mode*3
Message Trunked Mode*3
Call Queuing with Priority*3
Late Entry (UID & GID)*3
4 Priority Monitor ID’s*3
Remote Group Add*1
Failsoft Mode
Multi-Site IP Network Compatible
60,000 GIDs / UIDs
Wide Area Group Call
Auto Roaming Registration
Group Registration
SCAN
Single / Multi-Zone Scan / List Scan
Dual Priority Scan (Conventional)
FM Modes-General
25 & 12.5 kHz Channels
FleetSync®/II
DTMF Encode / Decode
Voice Inversion Scrambler
Analog Scrambler Board Capability
FM Conventional Zones
QT / DQT / Two-Tone
Call Keys 1-6
Operator Selectable Tone
FM LTR ® Trunked Zones
KENWOOD LTR® Features
FleetSync ® / II (FM)
PTT ID Digital ANI
Selective Call & Group Call
Status Messaging*1
Emergency Status
Caller ID Display
Short Text Messages*1
MDC-1200
PTT ID Digital ANI
Caller ID Display
Emergency Status
Radio Check
Radio Inhibit
*1 Requires NX subscriber unit PC Serial Interface compatible software application (e.g KENWOOD AVL & Dispatch Messaging software) or hardware (e.g.console).
*2 Requires KENWOOD OTAP Management software
*3 These trunked features are primarily system programming and operational dependent. Priority Monitor also requires NX subscriber settings.
NX-200 NX-300
GENERAL
Frequency Range | Type 1 136-174 MHz 450-520 MHz Type 2 400-470 MHz |
Number of Channels | 512 |
Zones | 128 |
Max. Channels per Zone | 250 |
Channel Spacing Analog | 12.5 / 15 / 25 / 30 kHz 12.5 / 25 kHz |
Digital | 6.25 / 12.5 kHz 6.25 / 12.5 kHz |
Operating Voltage | 7.5V DC ± 20% |
Battery Life (with KNB-48L) | 5-5-90 More than 14.5 hours 10-10-80 More than 9.0 hours |
Operating Temperature Range | -30°C to +60°C (-22°F to +140°F) |
Frequency Stability | ± 2.0 ppm ± 1.0 ppm |
Antenna Impedance | 50 Ω |
Dimensions (W x H x D) | Projections not included Radio only 58 x 127.5 x 41.3 mm with KNB-47L 58 x 127.5 x 41.3 mm with KNB-48L 58 x 127.5 x 48.5 mm |
Weight (net) | Radio only 260 g with KNB-47L 375 g with KNB-48L 405 g |
RECEIVER
Sensitivity Digital
@ 6.25kHz (3% BER) 0.20 μV
Digital @ 12.5kHz (3% BER) 0.25 μV
Analog (12 dB SINAD) 0.25 μV
Selectivity Analog @ 25 kHz 72 dB
Analog @ 12.5 kHz 65 dB
Intermodulation Distortion Analog 70 dB (±50,100 kHz)
Spurious Response Analog 70 dB
Audio Distortion Less than 3%
Audio Output 500 mW / 8 Ω
TRANSMITTER
RF Power Output 5 W / 1 W
Spurious Response 70 dB
FM Hum & Noise Analog @ 25 kHz 45 dB
Analog @ 12.5 kHz 40 dB
Audio Distortion Less than 3%
Modulation 16K0F3E, 11K0F3E, 8K30F1E,
8K30F1D, 8K30F7W, 4K00F1E,
4K00F1D, 4K00F7W, 4K00F2D
Analog measurements made per TIA/EIA 603 and specifications shown are typical.
Specifications are subject to change without notice, due to advancements in technology.
FleetSync® is a registered trademark of JVC KENWOOD Corporation.
LTR® is a registered trademark of Transcrypt International.
AMBE+2™ is a trademark of Digital Voice Systems Inc.
Windows® is a registered trademark of Microsoft Corporation.
NXDN® is a registered trademark of JVC KENWOOD Corporation and Icom Inc.
NEXEDGE® is a registered trademark of JVC KENWOOD Corporation in U.S.A. and some countries.
Applicable MIL-STD & IP
MIL Standard MIL 810C
Methods/
Procedures MIL 810D
Methods/
Procedures MIL 810E
Methods/
Procedures MIL 810F
Methods/
Procedures MIL 810G
Methods/
Procedures
Low Pressure 500.1/
Procedure I 500.2/
Procedure I, II 500.3/
Procedure I, II 500.4/
Procedure I, II 500.5/
Procedure I, II
High Temperature 501.1/
Procedure I, II 501.2/
Procedure I, II 501.3/
Procedure I, II 501.4/
Procedure I, II 501.5/
Procedure I, II
Low Temperature 502.1/
Procedure I 502.2/
Procedure I, II 502.3/
Procedure I, II 502.4/
Procedure I, II 502.5/
Procedure I, II
Temperature Shock 503.1/
Procedure I 503.2/
Procedure I 503.3/
Procedure I 503.4/
Procedure I, II 503.5/
Procedure I
Solar Radiation 505.1/
Procedure I 505.2/
Procedure I 505.3/
Procedure I 505.4/
Procedure I 505.5/
Procedure I
Rain 506.1/
Procedure I, II 506.2/
Procedure I, II 506.3/
Procedure I, II 506.4/
Procedure I, III 506.5/
Procedure I, III
Humidity 507.1/
Procedure I, II 507.2/
Procedure II, III 507.3/
Procedure II, III 507.4 507.5/
Procedure II
Salt Fog 509.1/
Procedure I 509.2/
Procedure I 509.3/
Procedure I 509.4 509.5
Dust 510.1/
Procedure I 510.2/
Procedure I 510.3/
Procedure I 510.4/
Procedure I, III 510.5/
Procedure I
Vibration 514.2/
Procedure VIII, X 514.3/
Procedure I 514.4/
Procedure I 514.5/
Procedure I 514.6/
Procedure I
Shock 516.2/
Procedure I, II, V 516.3/
Procedure I, IV 516.4/
Procedure I, IV 516.5/
Procedure I, IV 516.6/
Procedure I, IV
International Protection Standard
Dust & Water Protection IP54/55
Previous: Kenwood NX 220
Next: No Information